Natural gas, copper and steel pipework, meter outlet to appliance inlet — BS 6891 style 1 mbar check across multiple runs and branches.
Appliances
Pipe sections
Edit pipework
Fitting allowances (metres added per fitting)
Set these to the figures you work to. They apply to every section of that material.
Material
Elbow
Tee
90° bend
Copper
Steel
Save, load or start again
The job is kept in this browser automatically. To move it to another device, copy the job data and paste it there.
Method and limits
Gas rate (m³/h) = heat input kW gross × 3.6 ÷ CV. Net inputs are converted to gross × 1.11 for natural gas.
Effective length = measured length + the fitting allowances above (default 0.5 m per elbow, 0.5 m per tee, 0.3 m per 90° bend for both materials — adjust to the figures you work to).
Capacity at 1 mbar for 15, 22 and 28 mm copper and ½", ¾" and 1" medium-grade steel (BS EN 10255) comes from the standard BS 6891 style table (3–30 m), interpolated on a log scale. Under 3 m the 3 m figure is used; over 30 m it is extrapolated.
35, 42, 54 mm copper and 1¼", 1½", 2" steel are scaled by bore (d^2.67) from 28 mm / 1" and are estimates — check against the current table.
Steel runs are drawn dashed on the schematic. Auto-size keeps each section in its own material.
Section drop = (flow ÷ capacity at that length)^1.82 mbar. Drops add along each route; every appliance route must stay within the limit (1 mbar meter to appliance for natural gas).
All appliances are assumed to run together (no diversity). Natural gas only — not for LPG, CSST or MDPE. Verify on site with a working pressure check at the meter and appliance inlet.